METTLER TOLEDO™ Ion Selective Electrodes (ISE)
A selection of ISE probes for detecting concentration of various free ions.
5590.00 SEK - 17570.00 SEK
Product Code | Brand | Connector Types | Model | Measurement Range | Price | Quantity & Availability | |||
---|---|---|---|---|---|---|---|---|---|
Product Code | Brand | Connector Types | Model | Measurement Range | Price | Quantity & Availability | |||
11987811
|
METTLER TOLEDO™
51344706 |
BNC | perfectION CI- Combination Electrode | 1.8 to 35500 mg/L |
15565.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11977811
|
METTLER TOLEDO™
51344703 |
BNC | perfectION Ca+2 Combination Electrode | 0.02 to 40100 mg/L |
17570.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11997811
|
METTLER TOLEDO™
51344709 |
BNC | perfectION CN- Combination Electrode | 0.2 to 260 mg/L |
15565.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11907821
|
METTLER TOLEDO™
51344712 |
BNC | perfectION CU2+ Combination Electrode | 6.4 x 10-6354 mg/L |
17570.00 SEK
Each |
Please sign in to purchase this item. Need a web account? Register with us today! | |||
11967811
|
METTLER TOLEDO™
51344700 |
BNC | perfectION Ag+/S2- Combination Electrode | Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L |
17570.00 SEK
Each |
In Stock
Log in to see stock. |
|||
10566415
|
METTLER TOLEDO™
51344715 |
BNC | perfectION FI- Combination Electrode | 0.02 mg/ - saturated solution |
16187.60 SEK
Each |
In Stock
Log in to see stock. |
|||
11927821
|
METTLER TOLEDO™
51344718 |
BNC | perfectION I- Combination Electrode | 0.005 to 127000 mg/L |
15565.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11947821
|
METTLER TOLEDO™
51344727 |
BNC | perfectION NO3- Combination Electrode | 0.1 to 14000 mg/L |
17570.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11937821
|
METTLER TOLEDO™
51344721 |
BNC | perfectION K+ Combination Electrode | 0.04 to 39000 mg/L |
17570.00 SEK
Each |
In Stock
Log in to see stock. |
|||
10145642
|
METTLER TOLEDO™
51340263 |
S7 BNC Cable | perfectION DX223-Na+ Half-Cell Electrode | 1.0 to 1 x 10-7 mol/L |
5590.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11917821
|
METTLER TOLEDO™
51344724 |
S7 BNC Cable | perfectION Na+ Combination Electrode | 0.002 to 23000 mg/L |
7870.00 SEK
Each |
Estimated Shipment: 19-06-2025
Log in to see stock. |
|||
10067810
|
METTLER TOLEDO™
51340400 |
S7 BNC Cable | perfectION DX235-Cl- Half-Cell Electrode | 1.0 to 1.0-5 mol/L |
13265.00 SEK
Each |
In Stock
Log in to see stock. |
|||
11957821
|
METTLER TOLEDO™
51344730 |
BNC | perfectION Pb2+ Combination Electrode | 0.2 to 20700 mg/L |
17570.00 SEK
Each |
In Stock
Log in to see stock. |
|||
Description
- Prior to first use, rinse the electrode with distilled water and soak it in the appropriate standard for 24-48 hours and then fill with reference electrolyte (refer to table above)
- ISA (Ionic strength adjuster) solution required to be added to all calibration standards and samples prior to measurement for accurate results
- Refer to electrode user manual for appropriate ratio of ISA solution to sample volume
- Add filling solution each day before using the electrode (at least 2.5 cm above sample level in beaker)
- Be sure to screw cap tightly immediately after use
- The filling solution inside the electrode should not be allowed to evaporate, as crystallization will result
- For storage between measurements and up to three days, store in the appropriate standard
- For long-term storage, refer to specific ISE electrode user manual
- Sensing membrane will wear over time; each membrane can last about six months with normal use, but actual lifespan will depend on the type of samples that are being measured
- Competing ion interferences are common. Refer to ISE electrode user manual for potential interferences
- Compatible with METTLER TOLEDO SevenExcellence Benchtop, Seven2Go, and SevenGo Portable
- Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples
Specifications
4.75 in. | |
120 mm | |
Epoxy |