missing translation for 'onlineSavingsMsg'
Learn More

Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC

Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC are phases with six α-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.

Specifications

Diameter (Metric) 0.4 mm
Diameter (Metric) Inner 0.25 mm
Stationary Phase Lipodex™ A
Type GC Capillary Column
Max. Temperature For isothermal operations: 200°C, For short isotherms in a temperature program: 220°C
View More Specs

Alert:

Water as solvent is strictly forbidden for all cyclodextrin phases. It is recommended to dry the sample and dissolve it in an appropriate nonpolar solvent.


Description

Description

A major advantage of LIPODEX columns are that many compounds can be analyzed without derivatization. However, for certain substances, enantioselectivity can be favorably influenced by formation of derivatives. Regioselective alkylation and/or acylation of the hydroxyl groups leads to lipophilic phases with varying enantioselectivity, which are well suited for GC enantiomer analyses.

It is not possible to make a general prediction about which LIPODEX™ phase could solve a given separation task. Even for compounds with small structural differences or within homologous series, the enantiodifferentiation can be quite different.

  • Base material: cyclic oligosaccharides consisting of six α-cyclodextrin glucose units bonded through α-1,4-linkages
  • hexakis-(2,3,6-tri-O-pentyl)- α-cyclodextrin
  • Ligands: R2=R3=R6=pentyl; n=1
  • Recommended for carbohydrates, polyols, diols, hydroxycarboxylic acid esters, (epoxy‑) alcohols, glycerol derivatives, spiroacetals, ketones, alkyl halides
Specifications

Specifications

0.4 mm
Lipodex™ A
For isothermal operations: 200°C, For short isotherms in a temperature program: 220°C
Lipodex™ A
1 Each
0.25 mm
GC Capillary Column
Enantiomer Separation
Non polar
Videos
SDS
Documents

Documents

Product Certifications
Berichtigung von Produktinhalten

Bitte geben Sie uns Ihr Feedback zu den Produktinhalten, indem Sie das folgende Formular ausfüllen.

Name des Produkts

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.

Vielen Dank, dass Sie uns helfen, unsere Website zu verbessern. Ihr Feedback wurde übermittelt